Embolization of Giant Post-Traumatic Arteriovenous Renal Fistula using the Penumbra Occlusion Device
DOI:
https://doi.org/10.26676/jevtm.v5i1.175Keywords:
Arteriovenous Malformations, Embolization, Post Traumatic, RenalAbstract
A 48 year-old-man with history of abdominal trauma came to the emergency department reporting back pain. The patient underwent abdominal ultrasonography for lumbar pain with detection of voluminous vascular alteration. Immediately, computed tomography angiography (CTA) was performed that demonstrated renal artero-venous fistula with aneurysmatic dilatation. After multidisciplinary discussion, an endovascular treatment was decided upon. Angiography confirmed a high-flow renal AV fistula, and the aneurysmatic dilatation and very tortuous renal artery. The complex anatomic situation was resolved with neuro derivated embolic metallic spirals. Complete exclusion of the fistula and aneurysm was obtained. CTA after the endovascular procedure demonstrated that renal perfusion was completely preserved.
Published
How to Cite
Issue
Section
License
Copyright (c) 2021 Journal of Endovascular Resuscitation and Trauma Management
This work is licensed under a Creative Commons Attribution 4.0 International License.
Authors of content published in the JEVTM retain the copyright to their works.